How much solar power do I need? How many batteries do I need? How big of an inverter or generator should I buy? These are some of the most asked questions on the internet RV forums. They’re all good questions, but at the same time, they’re also completely impossible to answer without having a whole lot more information.
In this blog post, we’ll look at some very basic questions that need to be answered, how to accurately gather the right data, and then how to use that data to make an informed decision you can feel confident about. The process is both very straightforward AND a little ambiguous at the same time. But I’ll show you how to do the straightforward part, and then provide a little guidance and some additional resources to help with the ambiguous part.
What we won’t be discussing is the actual build-out of a solar system. Nor will we discuss any components outside of the batteries and solar panels. That’s not the point of this blog post. The real point is to determine how big (or small) your system needs to be.
OK, pay attention…class is now in session.

NOTE: We will be focusing mainly on the solar aspect. However, where it’s appropriate, I will also point out how this all applies to generators as well.
Basic Electrical Terminology
To make sense of what we’re about to cover, you need to become familiar (or re-familiarize yourself) with some basic electrical terms, concepts, and equations. Let’s first look at the basic definitions. Then we’ll see how they’re all related. Admittedly, these aren’t official definitions as I’m trying to just put them in plain language. And don’t skip this if you’re not familiar…it’s important!


Current (I) – Measured in Amps (A), this is the flow of electricity through an electrical system.
Voltage (V) – Measured in Volts (V), this is the driving force of all electrical systems. Voltage “pushes” the current through the system.


Power (P) – Measured in Watts (W) or Kilowatts (KW), this is the amount of work either being produced by the power supply (generator, battery, etc.) or being consumed by the electrical load (heater, pump, etc.).
AC Power – This is the power that comes from your 120V outlets. It powers things like your toaster, microwave, and air conditioner.
DC Power – This is the power that comes from your battery. It powers things like your USB outlets, water pump, and overhead lights.

Amp-hour (Ah) – This is a measure of how much power a battery supplies in one hour. For example, if a battery provides 50 amps for one hour, then it has expended 50 Ah. Similarly, if that battery provides 100 amps for half an hour, then it has also expended 50 Ah.
Watt-Hour (Wh) – Or Kilowatt-hour (KWh). This is just like the amp-hour except we’re now looking at watts instead of amps. So, if a battery supplies 1000 watts of power for one hour, it has supplied 1000 Wh, or 1 KWh of power.


The basic power equation – This is how it’s all related. It’s how you calculate either how much power something consumes (e.g., a toaster) OR how much power something provides (e.g., a battery).

Example
If a 12V battery is supplying 5 amps to a motor, then it’s providing 60 watts of power.
Power = 12 Volts x 5 Amps = 60 Watts
For this discussion we will always assume a voltage of 12V for DC power sources and loads, and we will always assume 120V for AC power sources and loads.
The same basic power equation is used for both AC power and DC power. Meaning, watts are watts, no matter if we’re talking about a 12V DC power system or a 120V AC power system.
In some cases, we may need to solve for current (amps), given the power and the voltage. In this case, we simply rearrange the basic power equation like this:

Using the same example as above, if we know the power being consumed by the pump is 60W, and the voltage is 12V, then:
Amps = 60 Watts / 12 Volts = 5 Amps
Now that we have the basics out of the way, let’s get on with the process.
Questions You Need To Answer
When I read those questions like, “How many batteries do I need?”, I don’t tend to answer them. It’s not that I don’t want to help, it’s just a much bigger conversation than what can be had on an internet forum. But if I did, the first thing I would ask is, “How much power do you use in a typical 24-hour period?”. Most people have no idea how much power they use. How can anyone know how many batteries YOU need or how much solar power YOU need if YOU can’t even tell them how much power YOU use? See where I’m going with this? It’s impossible.
What if I asked you how much gas I need to put in my car today? Most people would just tell me to fill it up and be done with it, but beyond that, how can you tell me how much gas I need if you don’t know some basic information? Information like how many miles I’ll be driving, what kind of gas mileage I get, and how much gas I already have. Without knowing this basic information, it’s impossible to answer my question, right?
Well, trying to determine how many batteries, how much solar power, or how big of a generator you need is no different. The process isn’t quite as easy as figuring out how much gas I need, but it’s also really not that much more difficult. Most people will just tell you to perform a power audit. What I’ll tell you is that performing the power audit is a very important step, but what do you do with that data? There are additional questions that need to be answered before you can do anything with that data. In all, you need to address these three basic questions before you can make an informed decision:

The more appliances and gadgets you want to use throughout the day, and the longer you use them, the more total amount of power you’ll need to supply. This is the power audit, and it’s critical that you get this part right.

This question is important to understand the necessary rating of inverter and/or generator required to power the loads. For example, if you need to run a big load, like an air conditioner, then you need a bigger inverter/generator. If you’re only powering small items like a TV or laptop, you can manage with a much smaller, less expensive inverter/generator.

This might influence your decision about how many solar panels you really need…if any.
IMPORTANT NOTE
In most cases, people discuss battery specs and capacity in terms of amps and amp-hours. However, for the purpose of this discussion I will be using watts (kilowatts) and watt-hours (kilowatt-hours). This is because, during this process, it’s easier to use watts than amps since most appliances and gadgets will list their power consumption in both amps (either AC or DC) AND watts. In the end, this will allow us to skip a bunch of intermediate calculations. Remember, watts are watts, no matter if it’s a 12V DC system or 120V AC system. Think of watts as being the universal language both systems speak. This is how we do it:
In our mock scenario, we’ll use typical 100 Ah batteries as examples. If you remember back to our definitions of Ah and Wh, and the basic power equation, then:
Power = Volts x Amps
This equation can also be used to convert amp-hours to watt-hours:
Watt-hours = Volts x Amp-hours
So, we can now discuss the capacity of a 100AH battery in terms of watt-hours:
Wh = 12V x 100Ah = 1200Wh, or 1.2KWh
Remember, battery specs are generally listed in terms of DC amp-hours. So, for all of those AC loads that list their specs in AC amps, we can skip a bunch of intermediate calculations converting to DC amp-hours by simply finding the total number of watts, or watt-hours, that need to be supplied to all of our loads, both AC and DC, during our power audit process. Then, in the end, we divide that number by 12V (battery voltage) to find DC amps and DC amp-hours. If this is confusing, don’t worry…just follow the process and it will all make sense in the end.
Mock Case Study
The easiest way to demonstrate this whole process is to just simply walk through a case study. Let’s start by looking at a specific (made-up) scenario and stepping through the three questions we identified above.
Check out our YouTube video above on performing the power audit. But don’t forget to come back here for additional information.
The Power Audit
Question #1: How much power will you use over the course of an entire day?
The power audit is the first, and most important, part of this process. This will tell you how much power you use in a 24-hour period, and there are a couple techniques you can use. The first is time consuming, and it involves figuring out how much power every load consumes individually, estimating how long they will be used each day, and then adding it all up to find out how much total power will be used.
The second technique is to use your surge protector, if you have the right kind (more on this momentarily), as a power meter to simply record the amount of total power used in a 24-hour period. This is by far the easiest way to do a power audit.
However, I highly recommend using both techniques, for a couple of reasons. First, finding out how much power each load consumes will help you better understand which items you can easily use when boondocking and which items you might want to AVOID using. Second, I like my checks and balances. If you use both methods, you should end up with similar results. If not, you need to figure out why. Let’s tackle the individual load technique first.
Individual Load Technique
Again, the goal here is to identify all the electrical appliances and gadgets you want to use while boondocking, how much power they use, and how long they will be used in a 24-hour period. Every item counts here, so be as detailed as possible. For our mock scenario, let’s assume you want to use the items below. We’ll fill in the table in a little later.
Item | Watts | Times | Total Minutes Used in 24 Hrs | Equals | Watt-hours |
| Coffee Maker | |||||
| Toaster | |||||
| Air Conditioner | |||||
| Laptop | |||||
| Ceiling Lights | |||||
| Maxxair Fan | |||||
| 12V Water Pump | |||||
| 12V Fridge | |||||
| TV | |||||
| Cell Phone Charger | |||||
Method 1: Use the data found on the item itself.
Typically, this information is on a sticker, or it’s stamped directly on the device. For example, my toaster has a sticker on the bottom that says, along with other information, 120V, 60Hz, 800W. I find this to be the least accurate method because most devices actually use more or less power than what the sticker/stamp says. It’s a decent number to use, if needed…it’s just not my preferred method.

Method 2: Use a plug-in watt meter.

These are handy because they’re small, and all you need to do is plug the watt meter into a 120V outlet, then plug your device into the watt meter and turn it on. Among other things, the watt meter will tell you how much power that device draws. If your device has more than one setting (high, med, low), you can run through those settings to see how much power each of them uses. This is a very easy and effective way to determine power usage for anything that plugs into a 120V outlet. One of the most popular brands is the “Kill A Watt” meter, and you can find them on Amazon for about $30.
Method 3: If you have one that provides the data, you can use your surge protector.
Some of the higher-end RV surge protectors, like the Hughes Power Watchdog, have apps that will provide this data. It will show you real-time data about how much power your RV is using.
Using the individual load technique, you can simply monitor the app while you start the load and note the increase in watts in the app. That will give you the power draw of each individual item. Again, if your device has more than one setting (high, med, low), you can run through those settings to see how much power each of them uses. This can be a little tricky, however, as the watts can sometime fluctuate, so I normally only use this when I want a rough idea of how much power something uses.

The Total Power Technique
Another way you can use your surge protector for a power audit is to do a boondocking trial run in your RV for a 24-hour period, while still connected to shore power, and capture your total power usage using the data from your surge protector app.
To do this, start the trial run in the morning and just act like you have no source of power other than your batteries for the entire 24-hour period. As soon as you start the trial run, reset your total power usage to zero in your surge protector app. Once the 24-hour period is up, just open the app and see how many total kilowatt-hours you used.
A few pro tips here:

Be sure to maintain a reasonable comfort level. You want to mimic boondocking to the maximum extent possible, but you don’t want to be miserable.
Don’t worry, if you want to use your AC when actually boondocking, you can account for that later, and I’ll show you how.


You want to make sure you’re using the freshwater pump since that’s an electrical load you will likely use when boondocking.
Mark these with yellow stickies ahead of time as a reminder that they’re not available. As a bonus here, you might discover some things that actually WILL BE necessary.

Now that we know what our options are, let’s use the individual load technique to determine how much power each load consumes and fill in our table.
Random assumptions have been made for total time used, and typical values have been used for how many watts each load consumes.
NOTE: To calculate watt-hours, use this equation:
Wh = (Watts x Minutes Used) / 60
Item | Watts | Times | Total Minutes Used in 24 Hrs | Equals | Watt-hours |
| Coffee Maker | 1200 | X | 5 | = | 100 |
| Toaster | 800 | X | 4 | = | 53.3 |
| Air Conditioner | 1800 | X | 120 | = | 3600 |
| Laptop | 180 | X | 120 | = | 360 |
| Ceiling Lights | 6 @ 9 watts ea. | X | 180 | = | 162 |
| Maxxair Fan | 20 (on high) | X | 480 | = | 286 |
| 12V Water Pump | 96 | X | 30 | = | 48 |
| 12V Fridge | 180 | X | 840 | = | 2520 |
| TV | 60 | X | 180 | = | 180 |
| Cell Phone Charger | 2.5 | X | 120 | = | 5 |
| Total Watt-hours | = | 7,314.3 |
These quick, simple calculations give a pretty good estimate of how much total power, in watt-hours, needs to be provided for an entire day. In this example, we can see you need to provide a total of about 7,300 watt-hours of power in a 24-hour period.
You may need to use a combination of these methods to determine how much power each of your devices draws. For example, you can use the plug-in watt meter to see how much power your toaster draws, but for your air conditioner (that likely doesn’t plug into an outlet), you might just use your surge protector to see how much the watts increase once the compressor is running. This method is also handy for all of those DC loads that don’t plug into an outlet, like your water pump. This might be confusing because your surge protector is measuring the total AC Load your RV is drawing. But your converter, the component that supplies the power to all your 12V DC loads, is powered by AC (e.g., shore power). Thus, your surge protector is in-fact measuring the entire load of your RV…both AC and DC.

Another option for the air conditioner is to use the specifications table in the user’s manual for your specific model. Having said all that, I’ll make this a little easier for you. RV air conditioners generally come in two sizes: 13,500 BTU and 15,000 BTU. You can expect the 13,500 BTU unit should draw somewhere around 1,400 watts. The 15,000 BTU unit should draw about 1,800 watts. For the properly operating AC unit, you can be pretty confident about those numbers when performing a power audit. All you need to do is determine how many BTU’s. Be careful here because you might have a mix of those units on your roof. More to come on this topic in the next section.
Ok, we spent a lot of time discussing the power audit, but that’s because it’s super important to get it right. You can’t accurately determine how many batteries you need, or how many solar panels you need, if you don’t get this part right. Now, let’s move on to the next question.
Maximum Required Power
Question #2: What is the maximum power you need at any given time?
This question needs to be answered to know how big of an inverter or generator you need. Fortunately, this is a relatively easy thing to do because most devices that you would actually use when boondocking in your RV don’t draw that much power. Without (well, maybe ALMOST without) exception, the item with the biggest power draw in your RV is your air conditioner. As you can see from the table we created above, when your AC is running, it can draw somewhere in the neighborhood of 1,800 watts. But that’s once it gets up and running.
The thing about AC units, though, is that they will draw significantly more power during the startup cycle, specifically, when the starting capacitor kicks in. When that capacitor kicks in, it can draw upwards of 40-60 starting surge amps! That correlates to anywhere between 4,800 and 7,200 watts! This is important, because you need to size your inverter or generator to accommodate for that starting surge.
Let’s say you want to start one of those 13,500 BTU AC units while you’re boondocking. That unit will have a surge of around 4,800 watts, so you need either an inverter or generator that can handle that much surge power. All inverters and generators have continuous and surge (peak) power ratings. For example, the Victron MultiPlus-II 3KVA inverter has a continuous power rating of 3,000 watts and a surge (peak) power rating of 5,500 watts. So, you could start that 13,500 BTU AC unit on this inverter. However, the 15,000 BTU AC unit will surge to 6,000 – 7,000 watts on startup, which is well beyond the capacity of the inverter. You’d need a larger, more expensive inverter to run that unit.
Fortunately, there’s an easy fix for this. Installing a “soft starter”, such as the Micro-Air Easy Start, on your AC unit significantly decreases the amount of surge power it will draw (by like 60-70%!). I recommend installing a soft starter in at least one AC unit as this will allow you to start that unit on nearly any source of power. We released a video on this topic (which I will reference shortly) a while back, so you can click that video below to see actual data and how effective these gadgets really are.
Back to our mock scenario…
So, let’s assume you have a soft starter installed on your 15,000 BTU AC unit AND you want to run that AC unit while boondocking. Referring back to the data I gathered on the soft starter in the video I mentioned previously, a 15,000 BTU AC unit will draw about 1,800 watts on startup, and about 1,650 watts once it’s running. That is well below the ratings of the Victron inverter mentioned above. However, keep in mind that there will likely be other loads running in your RV as well, so a 3,000-watt inverter is about the smallest you would need.

This same principle applies to generators. Generators also have ratings for the load they can carry continuously as well as ratings for surge power. Also keep in mind that dual fuel generators (that can use either gas or propane) are derated when operating on propane. For both inverters and generators, you simply need to understand what their starting and running capacities are and compare them to your own appliances and application.
Now, if you don’t need to run an AC unit, you can get by with a smaller inverter or generator. The next biggest appliance you’ll likely use is your microwave oven. Microwaves consume a significant amount of power as well, but not nearly as much as an AC unit. So, using a Victron inverter as an example again, the MultiPlus 2000VA should be more than adequate to run a microwave along with all the other loads.
Now that we know how much total power we need to supply in a 24-hour period AND the maximum power we need to supply at any given time, we can move on to the next question.
Length of Time
Question #3: How long do you intend to boondock?
This question is important because the answer will give you an idea of how many batteries you need and/or how much power you need to generate using solar panels. For generators, this is important to understand how much fuel (gas or propane) you’ll need on hand. The user’s manual for your generator will tell you approximately how long the generator will run at X% load on either a full or half tank of fuel.
Boondocking has different meanings for different people. Some only boondock for a night or two at a time, while others like to get off the beaten path for longer stretches. The key is figuring out what it means to you so you can decide what kind of system you need to build.
Let’s assume you only want to boondock for a night or two as you travel to your next destination where you’ll have full hookups. In this case, you may only need enough battery power to get you through a couple of nights and might not have a need for solar panels (or a generator) at all since you can recharge your batteries on shore power at your next destination. Usually, in these cases, you will use very little power while you’re boondocking. Some lights, maybe the microwave for a few minutes, the TV, and cellphone chargers might be the only things you use. If that sounds like your version of boondocking, then you can probably get away with just a couple of batteries.
However, you need to understand the difference between different types of batteries. Without going into a lot of detail about all of them, we’ll quickly look at three different types to get an idea of what to look for.
Quick definition. Depth-of-discharge (DoD). This is how far you discharge your battery. Meaning, if you use 20% of your battery capacity, then the DoD is 20%. If you discharge your battery down to where it has 20% of its capacity remaining, then the DoD is 80%.

Flooded lead-acid batteries are still the most common type of batteries. They’re relatively cheap, and there really isn’t anything wrong with them if they’re applied and maintained correctly. The DoD for flooded lead-acid batteries should not normally exceed 50%. This means if you have a single 100Ah flooded lead-acid battery, you really shouldn’t discharge it beyond 50Ah. Now, that doesn’t mean you can’t…it just means that you shouldn’t as these batteries will degrade faster the more you discharge them past 50% DoD. So, if you decide you need 100Ah of battery power to boondock overnight, then you actually need two 100Ah flooded lead-acid batteries.
Absorbent glass mat (AGM) batteries are also lead-acid batteries, but due to their construction, they can withstand a greater DoD consistently. Generally, you can discharge AGM batteries down to 80% DoD. Having said that, many AGM battery manufacturers still recommend you don’t consistently drain these batteries past 55% DoD. These batteries will cost more, but they have a higher DoD, will last longer, and will save you money in the long run.


Then we have Lithium-Ion batteries. LiFePO4 batteries are the most common type of Lithium-Ion batteries you’ll find in RVs. They’re significantly more expensive than lead-acid, but they also have significantly more capacity since they can be reliably discharged down to 90%-95%. This means you get to enjoy (nearly) the full capacity of the battery. Additionally, these batteries will last much longer than any lead-acid battery. They also weigh half as much as lead-acid batteries, which is a bonus in an RV!
NOTE: There are differing opinions on the DoD for Lithium-Ion batteries. Some will say you can discharge them all the way to 100% DoD. Others will say “nearly” 100%. And yet others will recommend not discharging past 80% DoD. No matter which number you’re comfortable with, they will still last longer, and perform better, than any lead-acid battery.

Back to what boondocking means to you. If you’re the type that wants to get away from it all for extended periods of time, then you will obviously need more, and better, batteries. For the serious boondocker, Lithium-Ion batteries are a must because you get (generally) twice as much battery at half the weight.
So, if we go back to our original example, how many Lithium-Ion batteries will you need to provide 7,300 watt-hours of power? To figure this out, we now need to convert those 7,300 watt-hours to DC amp-hours. Again, to do this, we simply rearrange the power equation and divide 7,300 watt-hours by 12V (battery voltage).
Ah = 7,300 watt-hours / 12V = 608.3Ah
That means if you want to ensure you can go a full 24 hours on battery power, you need a total of seven 100Ah Lithium-Ion batteries to provide the total amount of power needed. Well…sort of. That’s what you would need if you wanted to boondock for exactly one day, with no way to recharge your batteries. But no serious boondocking can happen if you don’t have a way to recharge your batteries, right?

So, if your goal is extended boondocking, then you’ll need to invest in some solar panels (or a generator) to recharge your batteries. But here’s the thing…if you now add solar panels (or a generator), how many do you need? How big of a generator do you need? And do you now actually need a full 700Ah worth of batteries?
The answer to these questions, again, depends on how long you want to boondock, mixed with a little personal preference.
Let’s start with how much solar power you need, which is the most difficult and, as I mentioned earlier, most ambiguous part of this process. If you want to boondock indefinitely, in this specific scenario, you will need enough solar panels to generate approximately 7,300Wh of power every day. The tricky part of figuring out how many panels that equals is figuring out how much sunlight there will be. On average, there are only about 4-5 hours of the day that will provide peak solar charging, and this can vary widely across the US.

There are a couple of cool websites, PVWatts and Unbound Solar, that will give you a good idea of what these peak solar charging hours are in different areas of the country. Both sites are pretty self-explanatory, so I won’t go into them in-depth here.
Keep in mind that your panels will still charge your batteries outside of the peak hours, but at a lower rate. However, to be conservative, we’re only going to consider the peak hours for solar charging AND we’ll assume the panels are in full sun. Be aware that panel placement, physical location, and weather conditions will affect how much sunlight your panels will get. Additionally, consider that not all solar panels are made the same. Some are more efficient than others, so pay attention to that when building out your system.
So, how do we calculate how many solar panels you’ll need to provide 7,300 watt-hours every day? Well, the formula below is a good starting point.

Where:
#SP = Number of Solar Panels Required
WHrs = Average Hourly Watt-hours
Pk Sun = The Number of Peak Solar Charging Hours per Day. (We will assume 5.)
Panel Watts = Solar Panel Output Rating, in Watts
NOTE: You need to find the hourly Wh demand by simply dividing the daily requirement by 24. In our case, that’s 7,300Wh/24 hrs= 304.2Wh.
So, for our mock scenario, we just need to input numbers. Let’s assume 5 peak hours and we’re using 400-watt solar panels. We have already calculated the hourly demand to be 304.2Wh.

Obviously, we can’t have 3.8 solar panels, so in this case, we round up to four 400-watt panels, for a total of 1,600 watts in our solar panel array.
Now, keep in mind that most people don’t boondock indefinitely. In reality, you may only want to boondock for 3-4 days. So, now you have to ask yourself two questions. 1) Do you really need 700Ah worth of batteries, and 2) do you really need 1,600 watts worth of solar panels? In my opinion, the first answer is “probably not”, and the second answer is “probably”. Let’s work through an example to see why.
We’ll assume you still need to provide the daily 7,300 watt-hours of power for 3 days of boondocking. We’ll also assume you don’t need a full charge on your batteries when you depart. In fact, we’ll assume you can leave on the last day with your batteries at 0%…because you were smart and installed Lithium-Ion batteries.
Now, let’s pretend you only have room for four 100Ah batteries and we now need to calculate how many solar panels you need to “survive” three days of boondocking. First, we need to convert that 400 (total) amp-hours of battery power to watt-hours for our calculation. From our basic power equation earlier, 400Ah at 12V converts to 4,800Wh. This means, for your three days of boondocking, your solar panels only need to produce (7,300Wh x 3) – 4,800Wh, or 17,100Wh of power.
Now, we simply go back to our equation to calculate how many solar panels you need (I’ll let you review that again on your own and jump straight to putting the numbers in). Just remember, we need to divide that 17,100 by 72 hours (3 days) to give the hourly watt-hour requirement.

In this case, you only need three 400-watt panels to last three days.
But…there’s always a “but”, isn’t there…if you decided to stay an extra day, then this calculation would tell you that four panels are needed. This just shows that this is all a balancing act, and there are many ways to approach it. For example, instead of getting that fourth panel, maybe you would prefer to just partially recharge your batteries with a generator. Or maybe you decide you just don’t need to use the AC on one of those days. The point being, there are a lot of ways to skin this cat. All you can do are do some basic calculations and get yourself in the right ballpark of where you want to be.
In the end, if you need to add one more panel or one more battery, it’s really not that difficult. The important thing is this: when you’re planning out your system, you should also plan for potential expansion in the future.
Generators
Up to this point, we’ve only touched on generators, and only in the context of determining how big of either an invertor OR generator you need to get off the grid. However, if you spend a lot of time in your RV, especially if you live in it like we do, I recommend you have a generator no matter what, and here’s why.
If you opt for a solar setup, no matter how big or how small, you WILL encounter less than optimal sunlight conditions for your solar panel array at some point. Whether it’s because the sun is partially blocked by trees, or because the weather just isn’t cooperating, you’ll need a backup plan to charge your batteries. Additionally, in the winter months, the sun is much lower in the sky, which means, even on the sunniest days at peak times, that sunlight just won’t hit your panels at the necessary angle to provide the maximum power output.
Generally, with a traditional solar setup, you can get by with a smaller generator to supplement. However, if you’re relying solely on a generator to get off the grid, then the size, again, depends on how much load you have. However, unlike a solar setup, you should be able to power your generator indefinitely with whatever fuel source it requires.
Generators, and their applications, are a whole separate topic that I might tackle in the future, but I’m not going any further into it in this post.
Don’t Overcompensate
As I said before, if you plan for potential expansion in the future, you’ll easily be able to add to your system. Start small-ish and see where it leads. You might find that you’re overestimating how much power you’ll really use when you’re boondocking. It would be a shame to spend tens of thousands of dollars on a system that you’ll never fully use.
Well…That’s It
There is certainly a LOT of information to digest in this post, right? It all might seem a little overwhelming at first, but if you follow this process, you should be able to build a system that will provide you with confidence that you’ll make it through that first boondocking trip without running out of power!


Well done! I added solar, batteries, and an inverter years ago and have been doing fine ever since but it is always nice to see a thorough and well written blog post on the topic to help newbies.
Thank you! The addition of solar has really opened up our options for places to get away from it all.
Great article! I really appreciate the clear and detailed insights you’ve provided on this topic. It’s always refreshing to read content that breaks things down so well, making it easy for readers to grasp even complex ideas. I also found the practical tips you’ve shared to be very helpful. Looking forward to more informative posts like this! Keep up the good work!
Thank you! Glad you found it to be helpful.